Wall Mount or Desktop Air Quality Monitor SQ30
Santacary SQ30 is a high precise instrument mainly used to continuously monitor the carbon dioxide (CO2) concentration, particulate matter PM2.5, PM10, the temperature and the relative humidity in ambient air.
High level CO2 in ambient air may cause fatigue, loss of concentration, and illnesses such as Sick Building Syndrome. Fine particles PM2.5 refers to fine particulate matter in ambient air aerodynamic equivalent diameter less than or equal to 2.5 micron particles. It was suspended for a long time in the air. The higher the fine particulate concentration and the carbon dioxide concentration in the air, the worse the air quality is. Studies suggest that long term exposure to fine particulate matter may be associated with increased rates of chronic bronchitis, reduced lung function and increased mortality from lung cancer and heart disease. The Wall Mount Air Quality Monitor SQ30 converts the concentration of CO2, PM2.5 in the air into visual data, and evaluates the air quality comprehensively.
SQ30 can be widely used in the houses, office, school, meeting room, restaurants, hospitals, mining facilities, metal refineries, commercial and public buildings, agriculture greenhouse, and other places where confined spaces for personal health and personal comfort is important. Santacary SQ30 is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
FEATURES
* Monitors CO2, particulate matter PM2.5 and PM10, RH, and Air Temperature.
Converts the concentration of CO2, PM2.5 into visual data,and evaluates the air quality comprehensively.
* Stable and accurate NDIR sensor for CO2 detection: Measurement Range 0~10,000ppm(1%Vol) CO2,Accuracy ±40ppm or ±3% of reading
* Detect atmospheric PM2.5 with laser scattering theory: Measurement range from 0 to 1000 μg/m3,
Particle count efficiency 50% @ 0.3 μm; 98% @ ≥0.5 μm;
* Minimum and Maximum Readings for all measurements;
* Easy-to-understand icons indicate air quality status.
* Large LCD display for easy to viewing:5.8 x 3.1 inch (Diagonal 6.5 inch LCD);
* Wall Mount or Desktop placement;
* Includes 5V Power Adapter.
THEORY OF OPERATION
1. CO2 Measurement: SQ30 uses Dual Beam Non-dispersive infrared (NDIR) principle to detect the existence of CO2 in the air. Automatic Background Calibration (ABC) is disabled.
2. PM2.5 and PM10 Measurement: SQ30 uses a laser scattering theory to obtain the number of particles in the equivalent particle size and volume units of different size through the algorithms based on MIE theory.
DEVICE
1. LCD display
2. Fahrenheit and Celsius switching button
3. MAX/MIN button
4. Power supply jack (DC 5V)
LCD DISPLAY
1. Trend Change Arrows (Up or Down)
2. PM10
3. PM2.5
4. CO2 concentration in ppm or x.xx% (>9,999 ppm)
5. Air Quality Indicator Icon
6. Air Temperature
7. % Relative Humidity
SPECIFICATIONS
PM2.5 Specification:
Measurement range of particles | 0.3 to 2.5 μm |
Particle count efficiency | 50% @ 0.3 μm; 98% @ ≥0.5 μm; |
Measurement range | |
Resolution | 1.0 µg/m3 |
Consistency of mass concentration of particles | ±10 µg/m3 @ 0~100 µg/m3; ±10% @ 100~500 µg/m3 |
Temperature Range | -10 to 50°C (14 to 122°F) |
Humidity Range | 0 to 90%RH |
Response Time | ≤10 Seconds |
CO2 Specification:
Measurement Range | 0~10,000ppm(1%Vol) display |
Display Resolution | 1ppm / 0.01% |
Accuracy | ±40ppm or ±3% of reading |
Repeatability | ±20ppm @ 400ppm |
Temperature Dependence | Typ. ±0.3% of reading per °C or ±4ppm per °C, whichever is greater, referenced to 25 °C |
Pressure Dependence | 0.13% of reading per mmHg |
Response Time | About 2 min for 90% of step change |
Warm-up Time | <5 seconds at 22°C |
Measurement Interval | 2 seconds |
Temperature Specification:
Temperature Range | -10.0~60.0°C (14~140°F) display |
Display Resolution | 0.1°C (0.1°F) |
Display Options | °C/°F switchable |
Accuracy | ±0.5°C (±0.9°F) |
Response Time | 5~30 seconds (device must equilibrate with environment) |
RH Specification:
Measurement Range | 0.0~99.9%RH |
Display Resolution | 1%RH |
Accuracy | ±4.5%RH |
Response Time | <8 seconds for 63% of step change |
General Specification:
Operating | 0°C~50°C (32°F~122°F), <95% RH non-condensing |
Storage | -10°C~60°C (14°F~140°F), <99% RH non-condensing |
Power Supply | AC adapter |
Dimensions | 235x165x40mm (9.2x6.5x1.6") |
Weight | 470 grams (16.58 oz.) |
INSTALLATION
Install the SQ30 at a location and height in the room where you want to test the air quality. Be aware that particulate concentrations and CO2 concentration can vary dramatically from one location to another within the same house.
MATERIALS SUPPLIED
1. Monitor
2. AC 5V >0.5A Adapter
3. Operation manual
COMPARED WITH LOCAL PM2.5 MEASUREMENT RESULTS
Amazon retail: https://www.amazon.com/dp/B079R8MB5T